Most Popular


Pass Guaranteed Quiz DP-900 - Microsoft Azure Data Fundamentals Perfect Valid Braindumps Pass Guaranteed Quiz DP-900 - Microsoft Azure Data Fundamentals Perfect Valid Braindumps
BONUS!!! Download part of ITexamReview DP-900 dumps for free: https://drive.google.com/open?id=1amoiDhg_q654gKXse6isVpYit6-DAambFirst ...
WGU Ethics-In-Technology Latest Training - Ethics-In-Technology Valid Exam Pass4sure WGU Ethics-In-Technology Latest Training - Ethics-In-Technology Valid Exam Pass4sure
BONUS!!! Download part of PrepPDF Ethics-In-Technology dumps for free: https://drive.google.com/open?id=1r_gAE9ihJdyKaMAiusuzwtn2kSwwAYyMTest ...
Official C-C4H47I-34 Study Guide - Pass Guaranteed 2025 C-C4H47I-34: First-grade SAP Certified Application Associate - SAP Sales Cloud Version 2 Exam Study Solutions Official C-C4H47I-34 Study Guide - Pass Guaranteed 2025 C-C4H47I-34: First-grade SAP Certified Application Associate - SAP Sales Cloud Version 2 Exam Study Solutions
P.S. Free & New C-C4H47I-34 dumps are available on Google ...


CDCS Examcollection Questions Answers | CDCS Latest Exam Questions

Rated: , 0 Comments
Total visits: 30
Posted on: 02/10/25

No doubt the EXIN EPI Certified Data Centre Specialist (CDCS) certification is one of the most challenging certification exams in the market. This EXIN EPI Certified Data Centre Specialist (CDCS) certification exam gives always a tough time to EXIN EPI Certified Data Centre Specialist (CDCS) exam candidates. The DumpsKing understands this hurdle and offers recommended and real EXIN CDCS Exam Practice questions in three different formats. These formats hold high demand in the market and offer a great solution for quick and complete EXIN EPI Certified Data Centre Specialist (CDCS) exam preparation.

The advent of our CDCS study guide with three versions has helped more than 98 percent of exam candidates get the certificate successfully. Rather than insulating from the requirements of the CDCS real exam, our CDCS practice materials closely co-related with it. And their degree of customer’s satisfaction is escalating. Besides, many exam candidates are looking forward to the advent of new CDCS versions in the future.

>> CDCS Examcollection Questions Answers <<

EXIN CDCS Latest Exam Questions, CDCS Test Certification Cost

The experts in our company are always keeping a close eye on even the slightest change on the CDCS exam questions in the field. Therefore, we can assure that you will miss nothing needed for the CDCS exam. What's more, the latest version of our CDCS Study Materials will be a good way for you to broaden your horizons as well as improve your skills. You will certainly obtain a great chance to get a promotion in your company.

EXIN CDCS Exam Syllabus Topics:

TopicDetails
Topic 1
  • Designing and Implementing a Data Centre: In this module, the exam assesses the knowledge of Exin data center professionals tasked with the design and implementation of data centers. Candidates will learn the key principles of creating an efficient data center layout, including considerations for scalability, redundancy, and security.
Topic 2
  • Data Centre Life Cycle and Standards: This section of the exam measures the skills of data center professionals and covers the various stages involved in the life cycle of a data center, from planning and design to implementation and decommissioning.
Topic 3
  • Data Centre Environmental Considerations and Efficiency: This section evaluates the proficiency of data center professionals in addressing environmental factors and promoting efficiency within data center operations. The target audience, including data center managers and engineers, will be tested on their ability to identify and implement measures that enhance energy efficiency, cooling management, and sustainable practices.

EXIN EPI Certified Data Centre Specialist Sample Questions (Q58-Q63):

NEW QUESTION # 58
When designing a data center network, your company wants to minimize the number of network switches to manage.
What type of physical cabling layout would be the best choice?

  • A. Star network design using coaxial cables
  • B. It does not matter as the number of switches is not influenced by the physical cabling layout
  • C. EoR (End of Row) design
  • D. ToR (Top of Rack) design

Answer: C

Explanation:
An End of Row (EoR) design minimizes the number of network switches, as multiple racks can share a single switch at the end of a row, reducing switch counts and simplifying management. This design centralizes network switching to fewer points, which reduces the complexity and number of switches required compared to a Top of Rack (ToR) design, where each rack typically has its own switch.
Detailed Explanation:
In EoR designs, each row has a single network switch that handles the connections for all racks within that row. This reduces the number of individual switches needed and centralizes network management, which is ideal for minimizing equipment and simplifying infrastructure in the data center.
EPI Data Center Specialist References:
EPI promotes the EoR design as a way to reduce switch counts and streamline management in data centers. This configuration allows for easier scaling and maintenance while maintaining efficient network connectivity.


NEW QUESTION # 59
From the options indicated, what is the correct starting point for the raised floor installation?

  • A. Point C
  • B. Point B
  • C. Point A
  • D. Point D

Answer: B

Explanation:
When installing a raised floor, the best starting point is typically from the farthest corner away from the entrance, in this case, Point B. This method allows for the floor installation to progress towards the entrance, ensuring that workers can avoid walking over the newly installed tiles, thus minimizing the risk of damage and maintaining cleanliness during installation.
Detailed Explanation:
Starting at the farthest corner (Point B) and working towards the entrance (Point A) is a standard practice in raised floor installation. This approach ensures that installers do not walk over freshly laid tiles, which could lead to shifting or misalignment. Additionally, it allows for more controlled placement and alignment, as well as convenient egress when installation is complete.
EPI Data Center Specialist References:
EPI guidelines for raised floor installation emphasize beginning at the farthest point from the entrance and working back towards it, which aligns with industry best practices for efficiency and quality assurance. This method reduces potential damage and supports precise alignment across the floor area.


NEW QUESTION # 60
What is the minimum requirement for the power feeds to the building for a Rated-3 data center based on the ANSI/TIA-942 standard?

  • A. Two feeds coming from two different substations, one power company is not acceptable
  • B. Two feeds coming from two different substations, one power company is acceptable
  • C. One feed from one substation split over two separated distribution boards in separate rooms
  • D. Two feeds entering the data center building from one substation

Answer: B

Explanation:
The minimum requirement for power feeds to a Rated-3 data center according to ANSI/TIA-942 is to have two independent power feeds, which can come from two different substations provided by the same power company. This ensures redundancy and concurrent maintainability, as each feed can support the load independently during maintenance or failure of the other.
Detailed Explanation:
The separation by two substations ensures resilience in case of a localized outage or substation maintenance, aligning with Rated-3 requirements for uninterrupted operation. ANSI/TIA-942 permits these feeds from a single utility provider as long as they are supplied from distinct substations.
EPI Data Center Specialist References:
EPI underscores the importance of dual power feeds from separate substations for Rated-3 facilities, highlighting that the ability to draw from different substations aligns with redundancy requirements for high availability.


NEW QUESTION # 61
A data center requires an audit to find out whether it conforms with ANSI/TIA-942 Rated-3 (concurrently maintainable).
Will the network architecture be part of this audit?

  • A. Yes, but only if the network administration does not comply with ANSI/TIA-606.
  • B. No, only the type of cabling used will be audited.
  • C. Yes, amongst other aspects, the network architecture should be Rated-3 compliant with the requirements of ANSI/TIA-942.
  • D. No, as concurrently maintainable only applies to electrical and mechanical (power and cooling).

Answer: C

Explanation:
For a Rated-3 data center, network architecture is indeed a key component of the audit under ANSI/TIA-942. This rating requires concurrent maintainability across all systems, including telecommunications infrastructure. The network architecture must therefore meet specific redundancy and reliability standards to ensure uninterrupted operations during maintenance or failure of any single component.
Detailed Explanation:
Rated-3 requirements extend beyond electrical and mechanical systems to include network architecture. This ensures that telecommunications systems are also designed for concurrent maintainability, thus contributing to overall uptime and resilience.
EPI Data Center Specialist References:
EPI endorses comprehensive assessments for Rated-3 facilities, emphasizing that network systems must meet standards for redundancy and concurrent maintainability, which align with ANSI/TIA-942's holistic approach to data center reliability.


NEW QUESTION # 62
A data center is located in an area where the demand for power is higher than the utility power company is able to deliver. This results in frequent power outages and, therefore, power shedding (scheduled/controlled power shutdown for areas) is frequently applied. The mains power is more than 650 hours/year not available.
What type of generators should be installed?

  • A. Continuous generators should be installed, at least in an N+1 configuration
  • B. Standby generators should be installed in at least an N+1 configuration
  • C. A combination of standby-, prime-, and continuous-generators, as the duration of the power outage is unpredictable. The total available capacity of the generators should be at least 500% of the data center load
  • D. Continuous generators should be installed; no N+1 configuration is needed as the generators will run all the time

Answer: A

Explanation:
In areas with frequent and extended power outages, continuous generators with at least an N+1 configuration are necessary to ensure consistent power availability. Continuous generators are designed for prolonged operation, making them suitable for scenarios where utility power is frequently unavailable, as in this case with outages exceeding 650 hours per year. An N+1 configuration ensures redundancy, which is critical for maintaining uptime in a high-availability data center.
Detailed Explanation:
Continuous generators provide reliable power over long durations, unlike standby generators, which are intended only for short-term use. The N+1 configuration ensures that there is always an additional generator available in case of failure, thus maintaining power supply even if one generator goes offline.
EPI Data Center Specialist References:
EPI best practices recommend continuous generators with redundancy for data centers located in areas with high power instability to maintain reliability and continuous operation.


NEW QUESTION # 63
......

Nowadays, seldom do the exam banks have such an integrated system to provide you a simulation test. You will gradually be aware of the great importance of stimulating the actual exam after learning about our CDCS Study Tool. Because of this function, you can easily grasp how the practice system operates and be able to get hold of the core knowledge about the EXIN EPI Certified Data Centre Specialist exam. In addition, when you are in the real exam environment, you can learn to control your speed and quality in answering questions and form a good habit of doing exercise, so that you’re going to be fine in the EXIN EPI Certified Data Centre Specialist exam.

CDCS Latest Exam Questions: https://www.dumpsking.com/CDCS-testking-dumps.html

Tags: CDCS Examcollection Questions Answers, CDCS Latest Exam Questions, CDCS Test Certification Cost, Valid Dumps CDCS Pdf, Updated CDCS Testkings


Comments
There are still no comments posted ...
Rate and post your comment


Login


Username:
Password:

Forgotten password?